Clik here to view.

EDS Hardware Wizard is not installing EDS Files

Ok, found a weird problem that I can't find any tech connect tickets or posts that solve my problem. Looking for other ideas. What I got going on is I am trying to register an EDS file. I use the EDS...

View Article


How to scroll faults in ML1400 and PV800?

Hello Friends I have a ML1400 program with 10 message faults aprox. and a PV800 program  with a Multistate Indicator showing the faults. When exists only 1 fault, the HMi is showing correctly 1 fault,...

View Article


Image may be NSFW.
Clik here to view.

Motion Servo Axis

Hello everybody,   I have the following situation:   I use the MAM function to move a servo axis; It also moves and stops  correctly when the condition before turns flase. The result is actually good,...

View Article

232 DH+ Pass through 5/04 PB32

I have an old system that needed some HMI modifications, it comminucates with DH+. The 232 port on the HMI does not work even if I disable the printer. I have tried to create a memory card with a...

View Article

Learning about MicroLogix 1500

I am new to Allen Bradley and am experimenting with a MicroLogix 1500 system. Base is 1764-24BWA Series B, Processor is 1764-LRP Series C. I only have 110V hooked to it right now, just seeing if I can...

View Article


Image may be NSFW.
Clik here to view.

PowerFlex 40-E AC Drive 22-COMM-E

Hey Everybody, i have some issue on understanding why they did like on the picture. Where are the Alarms coming from? I think from the Powerflex but where can i check which alarm is enable or not? I...

View Article

Image may be NSFW.
Clik here to view.

Remove Protection on floats micrologix 1400 lcd screen

Hi,   I'm writing a short code to deduce the speed of a rotor using the time it takes between pulses of a rotation sensor, and use this value to determine if it is underspeed/ overspeed / correct -...

View Article

When to use HSC

Good morning all, i need some advice about when to use a HSC, processor is L33 and i have two pulse inputs one at max 53Hz and the other at max 117Hz will this require a HSC?   Thanks in advance

View Article


RSLogix 500 Version 3

I have came across some Allen Bradley SLC processors with no backups running version 3 firmware. Does anyone have software that old or a connection? Rockwell will not support. Any assistance will get...

View Article


HSCE2 card doing strange things, Help needed.

Hello, New guy here but been around plc's for a while.  I'm doing a controls retrofit on a press brake and using a SLC5/04 with both a HSCE card and a HSCE2 card in it.  The HSCE card works fine and...

View Article

Structured Text Value for Pi?

Is there a built in value (tag) for Pi in structured text or do I just use a constant?

View Article

Advice on choosing a PLC for a project

Awhile back I posted about my project which I am doing to learn how to program PLC's I took an unusual approach and built a model railroad layout using parts I scavenged from machines that were being...

View Article

Atlas Copco OpenProtocol

I am not sure that this is the correct forum, but since we will be using a ControlLogix PLC I posted here. I am looking for drivers and/or example source code for both PC and AB PLC based systems that...

View Article


PLC5 to Controllogix Tricks?

I have to replace a PLC5 with a new 1756-L73. There are (3) panels involved in system. The main panel controls (2) other panels remotely via each their own 1771-ASB module. Time is of the essence on...

View Article

1756-EN2TR communication error

Presently we are using 1756-EN2TR modules for the communication, upto now plant was running without any issue but recently we have started to experience 1756-EN2TR communication failure , Due to the...

View Article


Image may be NSFW.
Clik here to view.

AB 5830 - safety output fault state

Hi, I have problem with 5069-obv8s, trying to use it for a first time just to power relays and contactors. All outputs are in internal fault, even if their are not conected. The card is set to use...

View Article

micrologix 1200 C series Modbus configs

Hi,I've got a ML 1200 C series with only 1 port and would like to connect to our DCS via Modbus. Since there's only one port, I've decided to employ a 1761-NET-AIC+ to provide for extra ports for...

View Article


RPI as Related to Scan Time

I have a CompactLogix and some Remote I/O, which I am communicating to using implicit messaging over EtherNet/IP. I'm curious as to the relationship between scan time and Requested Packet Interval...

View Article

Powerflex 70

Hi Everyone! I need some help with configuring an inverter. The inverter type is powerflex 70. How can I set the next parameters. It should be work with two speeds.  First:  around 40 Hz.  Second...

View Article

Powerflex 527 rotating after MSO instruction

I am controlling the powerflex 527 drive with MSO instruction, first setting the drive on and then running the motor with MAJ instruction. After MSO instruction, motor is rotating about 2 sec and then...