Another Newbee Question

Hello agian, Trying to write a program for water tank levels, problem is the tanks have over 37000 gallons of water in each but I can only get sums up to 32767 before I get a math overflow fault. Could...

View Article


Major Fault RS Logix 5000

Hello My emulator go to fault state as soon as it goes online and runs (Within a second) and the following error  Code 01, (May have been caused by an infinite loop, a complex program, or a higher...

View Article


Connecting InTouch 2014 to AB 1769-L33ER

HiWe have a project that is based on an AB 1769-L33ER and I need to connect this to our InTouch 2014 Scada system.We have installed the latest ABCIP IO Server and are ready to connect.Can you directly...

View Article

1756-L61 ControlLogix 5561 losing program

Hello guys, I am having an issue with 1756-L61 ControlLogix 5561. I just had a power outage and when i tried to go online, it says there is no program in the controller.  The controller's revision is...

View Article

Square Wave Problem With Micrologix

Hello all, this is my first post. I am using an AB Micrologix 1400 (1766-L32BXB Ser C FW 21). I was trying to generate a pulse train using the PTO instruction. I have modified PTOX funct. file. The...

View Article


Kinetix Vertical Axis Program Mode

I am looking for how others have set up vertical axis motions using the Kinetix 5700 servo system. I have a 2 axis pick/place unit with a horizontal axis (X @ 2500mm) and vertical axis (Z @ 1200mm)...

View Article

Is there a method to index and array of a UDT?

Hello all,   I am working with an Rockwell  1769-L18ER PLC and Studio 5000 version 32.  I am trying to setup an array of my UDT and index thru the array with a DINT.   I assumed the syntax would be...

View Article

Soft PLC First Scan

Good day. I am running a OTS, training simulator, using Rockwell RSLogic Emulate soft PLC.s. We have the configuration from the site. This is connected to a Hysys math model that gives us the I/O. We...

View Article


PLC 5/40E Communication

Looking to add 3 new proface HMI's over ethernet to an existing PLC 5/40E Rev E.2. Does anyone have any experience do this? My concern will be delay in communication with that many devices. I have...

View Article


Excel VBA to CLX data dump

Good afternoon, I'll start by explaining what i want to do and then what I've tried. We have an excel document at work that contains our material batch information and there is a column of data i...

View Article

MDS instruction would not complete

Hany any you of guys dealt with MDS instruction not completing and being stuck on .EN bit but the motor itself just stopped running out of nowhere? I did read the tech note on this on Rockwell's...

View Article

Two problems on two different computers

Problem 1: Laptop doesn't recognize the license dongle. FlexNet server stopped and won't start (Flexnet doesn't ring any bells, is that the right server for license files?). No license available My...

View Article

Encoder connection to Micrologix 1100

I have been tasked with collecting linear footage data of our product; after exiting the extruder it contacts a measuring wheel attached to an BEI encoder 28V/V. I've connected the ML1100 24 volt to...

View Article


JXR Instruction

Does anyone know how to set up a JXR instruction. I would like to use another routine if a manual set is required, and use the auto routine if normal run conditions are correct. 

View Article

Powerflex 70 Speed Command

I've set up a Powerflex70 to communicate with a L32 Compact Logix via 20-Comm-E ethernet. Every thing is working correctly except the speed command. When I send it a speed reference of 14.6 Hz (146 in...

View Article


Disabling Web Server

Hi. As part of a cyber security review, we have discovered recently that an SLC5/05 PLC has the http server enabled. I have tried to disable it by removing the the tick from the tick box on the...

View Article

Run Powerflex 525 from keypad?

I'm having trouble with some Powerflex 525 drives. Right now what I need to do is run them manually from the keypad to test conveyor belts.  Is there a way to do this and if so how?   Thanks in advance.

View Article


last 10 pcs average cycle time

Hello All Does anyone have a simple way to calculate the average cycle time of the last 10 parts ran, doing a live update every part? I am using Logix 5000 and my machine makes a part every 4.0 - 6.5...

View Article

Image may be NSFW.
Clik here to view.

Software for PanelView Plus 600

Hello everyone, I need help with a problem in a machine I'm currently working on. It has a PanelView Plus 600 HMI and SLC 5/04 PLC. The HMI is non responsive and I've been tasked to determine if it's...

View Article

Image may be NSFW.
Clik here to view.

How do I find out if a poweflex vfd LP or HP?

Hi guys, I am trying to use ControlFlash to downgrade a powerflex's firmware version. It is asking me if it is HP or LP. How do i know if it is LP or HP? Thanks  

View Article