Micrologix 1100 Write to Modbus compressor
Hey guys, I'm using a micrologix 1100 to communicate through Modbus to a Ingersoll rand Air Compressor (controller is a xe-145m) and air compressor is a R110i. I have multiple read and writes going to...
View ArticleCisco / Stratix Networking Training
I am looking for e-learning or preferably classroom training which will enable me to better understand what I am doing when I am setting up statix switches. Things like VLAN, PTP, DLR and so forth. I...
View ArticleACD File to pdf conversion
Hello friends, I m struggling to open the project file in acd format. Can you please open it and convert it in to PDF . Many thanks in advance for the support. but the basic problem is I m not able...
View Article1756-EN2T Anomalies
I have a 1756-ENBT Card in a 7 slot rack. Tried swapping it to a 1756-EN2T configured identically for ip/subnet/gateway and could not ping it from the very same programming terminal that had beena...
View ArticleJoining HMI PC to domain using FT SE
Hello,We have a customer who wants to connect the HMI PC of FT SE to their domain and to use their own authentication. After investigating the application, it seems our application uses a...
View ArticleUDP Communication to PC using MSG instruction
Hi All I need to receive data from a PC application using UDP on my Logix5563 PLC, Is there any example applications that I can follow? as the documentation does not really guide you for UDP open...
View ArticleLooking for better way to copy array into individual tags
I am copying some data from a vendor PLC through MSG instruction into my PLC through CIP data table read. Is there a better way to break down this array of data into individual real tags through an...
View ArticleHow would you interpret this CPT
Destination: FxTblStart ; this is an integer that is used as a pointer for some interesting array "stuff" (see PDF link below) Source: FxNo-1 AND 7 In this case FxNo = 20 20-1 = 19 AND 7? AND is a...
View ArticleSLC 500 and SMC Ex260
I'm trying to connect a SMC EX-260 to a Allen Bradley Micrologix 1400 PLC so I can run some valves with it. However, RsLogix 500 doesn't allow me to just setup a generic ethernet device like I would...
View ArticleDelay transfer signal between 2 controller logix
Hello. I have main PLC L73 with redundancy module, and 4 others controller as L71, L72 (S/R A,B, CSU A/B). They connected through control net network as my attached document. I created message to read...
View ArticleAllen Bradley 1756-L62A CPU compatibility with 1719 EX I/O
Dear All, I want to communicate Rockwell 1719 EX I/O with 1756-L62A CPU using 1756-EN2TR over Ethernet. Please help me whether it is possible or not? Thanks
View ArticlePDF viewer on PV+
Good morning. I have a PV+ HMI and have loaded a few PDF documents onto the HMI. Is there a way to access and open the PDF's from a button on the HMI? The PDF's reside in a Windows folder I created...
View ArticleASCII String to LREAL number
I have a function that reads ASCII code from a transducer, converts the code into characters and places the characters from the serial buffer into a string. Now, I am trying to convert the value in...
View ArticleRSLinx and PLC 1747-l553
Good afternoon, dear specialists. Recently, only without preparation, I began to set up communication between the scada and the PLC. The problem is that RSLINX LITE (v3.90.01 CPR 9 SR9) sees both...
View ArticleRun Powerflex 525 from keypad?
I'm having trouble with some Powerflex 525 drives. Right now what I need to do is run them manually from the keypad to test conveyor belts. Is there a way to do this and if so how? Thanks in advance.
View ArticlePanelView 800 Recipe Management
Hello guys, I'm a new guy with Panel View 800 and I have few questions from beginning. I have an application 2x PV800 4" and 1x CompactLogix L24ER.This application require recipe management and I've...
View ArticleMicro 850- ASCII query/command and response
I have been working on a PLC project that requires sending ASCII commands/queries to an external pressure transducer using the Micro 850 PLC (2080-SERIALISOL module) via serial port communication...
View Articlewhat does this formula do ?
I have the below formula in CPT instruction (not able to attach any pics)... IO_Rmc_Data = (IO_Rmc_Data+1) MOD 10 What does MOD 10, MOD 1000, MOD 10000 do ? On help it says it stores the remainder of...
View ArticleVM With Studio 5000, FTVSE, Emulate 5000
Ok, so I was tasked with setting up a virtual for our development team to be able to use to quickly deploy projects hmi, emulated plc, and studio 5000 project together on one virtual. The main reason...
View ArticleGP PRO proface programing
Hello guys, Can anyone help me about how to make a growing circle with proface program :). I would like to control it by a real tag or so on. Like if the real tag is getting bigger the circle has to...
View Article