PF527 syncronizing, not connecting

I have two PF527 devices in a bus. These are in the same motion group. If I take the ethernet cable off, it will not connect the PF527 anymore back to the be controlled. I can find it on the net (ping...

View Article


How to open .ecx type files

How to open .ecx type files. Diagnostic data of the Control logix CPU's

View Article


CCW Developer and Developer ESD

Hi, i would like purchasing a CCW Developer edition but our distributor send me quotation for 2 versions. CCW Developer Edition and CCW Developer ESD  CCW Developer Version is known bud what is the...

View Article

Image may be NSFW.
Clik here to view.

How to configure RTD - 1746-NR4

Hi, I have inserted new RTD module into in my SLC500 as replacement to defected RTD module however the module LED is enabled but the channel LED's are blinking. I have checked the following: In the...

View Article

Image may be NSFW.
Clik here to view.

Output Addressing RsLogix500

Hi Everyone, I've been studying some plc programs at work and I have a question. Why an output would be addressed as O:[N48:1].0/[N47:1]?. Also, when I force that output the state of O:0/8 in the data...

View Article


Image may be NSFW.
Clik here to view.

RTD - 1746-NR4 color RED or Green

Hi, I have new RTD module the same specification as the old one however looking to the front face of the RTD a difference can be seen: The old module is GREEN The new module is RED   Anyone can tell...

View Article

Troubleshooting 1746-NI4

Hello Everyone , Please Guide me, Can we Check the Allen Bradley  Analog Input  Module SLC 500 1746-NI4 with the Digital Multimeter without being installed in the Rack, Thanks for all.  

View Article

Allen Bradley Products

Hi, I am looking for Allen Bradley spare parts, Who can recommend me a good source in the UK or elsewhere in europe?          

View Article


Image may be NSFW.
Clik here to view.

ASCII conversion

Hello, Need help converting a DTOS, ASCII representation Value back to actual TEXT of the barcode read. I get a DINT from the barcode reader. I stored it to a STRING tag using CPS and can View it in...

View Article


Allen-Bradley Panelview Plus 1000

Thank you in advance. My Panelview Plus 1000 the screen does not turn on anymore, but the machine still functions normal. There is a red fault light that appears in the back. i have tried resetting...

View Article

Dynamic Arrays and Data Entry Studio 5000

So we have a PLC project coming up and its our first one and understand and can execute most of the sequence without issue.  The part that is getting me is how to handle the following efficiently...

View Article

Factory Talk View SE - Application Migration

I have a running Windows 7 System with Factory Talk View SE Distributed Network Application Version 6.10 running both server and client functions. I need to move this to a Windows 10 System with...

View Article

Factory talk text"output"

I have a INT between two control systems.  The destination is a allen bradley plc.  I am running studio 5000.  The INT  indicates current step in sequence.  I have made a HMI screen in Factory talk...

View Article


ML1400 RSlogix Micro

I was brought the problem at work of an ML1400 PLC being programed with RSLogix micro. They wanted to open and edit the program but only had RSLogix 500 to do so. They said they could download the...

View Article

Micrologix 1500 1764-24AWA LSP Series B Cannot Use Floating Point?

I am attempting to transpose an old Micrologix 1200 program to a newer Micrologix 1500 processor. I was surprised to find out there was no F8 data file, nor can I create one through the menu system....

View Article


Micrologix 1500 Apu step 4 watchdog fail.

 I have liquid nitrogen plant linit 25 I have a problem in micrologix 1500 LRP Plc give error.APU watch dog failure or apu step 4 failure 

View Article

NET-ENI CONFIGURATION UTILITY

Rockwell seem to have completely removed the 1761 NET-ENI configuration utility which does seem a bit mean bearing in mind their is still a lot of this stuff about (as I have just found out) Does any...

View Article


Panelview plus 1250 v8

Hi guys it's been a while since I've been here. Just wanted to know ,is it possible for monitoring purposes only to connect 2 x plc5s through the rs232 ports connected to a panelview plus 1250 serial...

View Article

Firmware Update

I am looking help with an issue I have trying to connect to a 5370 Controller 1769-L33ER. The controller firmware is 20.014 and my studio does not have 20.014 firmware. I have downloaded the firmware...

View Article

Masked moved instruction

Hi guys, I'm studying the Masked MVM instruction. Now I know what it does but can anyone tell me an example of an application in real life. I mean where would I use it? If I'm integrating something...