A-B Ethernet ActiveX Control
Dear Colleagues, I have developed a program where in i am using A-B Ethernet ActiveX Control (Asabtcp.ocx). but now i need to use the licenced version, how can i get it and where can i get it. I also...
View ArticleCant set output on 1734-OB8E
Hi, I have a 1734-OB8E module on a POINT I/O system. In the hardware configuration, everything looks fine. However, I am not able to energize any outputs on the card. What could be wrong? Working in...
View ArticleWhich Windows OS to use for RSLogix 5000 V13.03.00?
I have some older RSLogix 5000 software I would like to run on a newer Dell 64bit laptop. It's RSLogix 5000 V13.03.00. I can buy a full Windows license for an older Windows OS and not connect to the...
View ArticleRSLogix 5000 DINT to INT
Evening, I need to read analogue value from Compactlogix PLC, this value is currently displayed as DINT. I will need this to be displayed as INT (I have SLC PLC reading this analogue and SLC doesn’t...
View ArticleProsoft AN-X4-AB-DHRIO
Hi, Has anyone used a ProSoft AN-X4-AB-DHRIO to convert ethernet from iFix V3.5 SCADA to DH+ on SLC5/04 PLC's at all? We are looking to use this but have had some comments that the ProSoft unit can...
View ArticleNew to Studio5000 FBD (Advice Needed0
In the screenshot, I have 2 level sensors that are being compared into an average. I want to remove the compare and do something like lead/lag. I'm looking for suggestions for which FB is best to use...
View ArticleRedundant Owner field in Network Connection Parameters
In the Forward Open message of EtherNet/IP, there are two Network Connection Parameters, one for Originator->Target, the other for Target->Originator. Volume 1 of the CIP specification...
View ArticleJogging powerflex 525 in hand mode
Hello all. First time poster. Im sure this has been asked but i cant seem to figure this one out after looking at the manual and browsing the forum. So we have a powerflex 525 at work. Essentially...
View ArticleAllen-Bradley PowerFlex700 interface Overview
Rockss Automation Various industrial control accessories such as the Allen-Bradley panel, board card and other industrial control accessories for a long time,The following introduces a panel of...
View ArticleError 54
Hello ,please how to fix error 54 in kinetix 5700 drive , I checked the wiring, motor and encoder are not problem, the motor does not work when you command the drive to start the error
View ArticlePanelView Plus 7 Standard - Trend Objects and Data Log Model
Hello, I have a PV Plus 7 Standard (VER C, Windows CE) and can't get a trend object to populate with past data when the object is opened. It simply initiates blank but then slowly populates over...
View ArticleKinetix 5500 Control Sync Fault
Problem: I am getting a control sync fault on 2 recently installed kinetix 5500 but only when my programing PC is connected to the machine network. Install and setup all went great over a 5 day...
View ArticleSlave EIP Device will not communcation as Generic Device only EDS File
Has anyone ever ran into the fact that you have a Slave EIP device, and it works ok when you use the EDS file, however if you try and configure it as a Generic Connection, it doesn't communicate to...
View ArticleConveyor tracking
Hello Guys, I have a Mitsubishi A8000 series vfd with an encoder card and also encoder. With analog (0-10V) signal i can read back the current speed. The conveyor convey paper sheets. Occasionally...
View ArticleFactory Talk View Studio ME - Cautionary Tale
This is a Factory Talk View Studio ME - Cautionary Tale I share in hopes it saves someone some headache. I had a Panelview Plus 7 Professional 1500 HMI firmware version 10 running an application built...
View ArticleUsing Cellular Comms for Remote I/O
Any advice out there for using Point I/O with CLX over cellular comms? We can ping the Point I/O from home base, and the Point I/O shows up in RSLinx from home base.
View ArticlePLC5 with Delta DOP HMI
Dear All Can I connect PLC5 with Delta DOP HMI via ethernet? Thanks
View ArticleAny safety PLC to replace PILZ plcs?
Hi guys, Our automated equipment is using PILZ PLC and we are trying to replace it. Is there any other safety PLC that can be replaced for the PILZ PLC? Thanks
View ArticleMicrologix 1400 PLC
Hello Experts Fault LED is blinking in Red in Allen Bradley Micro Logix 1400 PLC Can someone please advice on how to fix this & probable reasons ? Can trial version of communicating software be...
View ArticleKinetix 5500 MAM .Err 11
Hello, I hope somebody can help me give me hint on where I could look. I do have an MAM command that is throwing error 11. "At least one axis is not configured to a physical motion module ora has...