Configure a Logix5000 Message?
Hi, guys, how’s going? If we want to configure a Logix5000 Message, then send it from controller AA to controller BB, should we add controller AA on controller BB I/O Configuration? Or we just need...
View ArticleControl Logix Memory Allocation
I am trying to better appreciate memory usage in CLX processors in an effort to create leaner programs. If I create a single DINT with a tag name one character long (ie tag "i" of type dint) in an L61...
View ArticleDifference between 1747L552B/C and L552
Hello, i would to know if there is differences to replace a 1747-L552B/C CPU with a 1747-L552. We have some problems to find in Europe a exactly type of this cpu (it's also much expensive), but there...
View ArticlePanelview 600 plus backlight
Is there a way to have the HMI do a quiet boot? I would like to have the backlight off while booting since the application is for a dark room. I am using RSlogix 500 with a micrologix 1500 controller.
View ArticleAllen Bradley fail safe IO module ??
what is CAT No. of Allen Bradley fail safe IO module?
View ArticleActivate rslogix500& rslogix5000
Hello. I have the original software ( rslogix500) on my pc. For some reason I enforce to format the pc and setup the new windows version, after that I install the rslogix500 but it didn't activate .
View ArticleSequence Instructions question
Hi, I’m working on a project in which the process has some sequences that I believe I can program using the SQI and SQO instructions. I usually avoid utilizing the built in sequence instructions but...
View ArticleAfter a power outage, Logix5561 lost the program?
Hi, guys, how’s going? Two weeks ago, after a power outage, Logix5561 lost the program, so we had to download the program to the controller. Then we installed a new battery (which we bought 2...
View ArticleInput Module Configuration or compatibility Issue
Dear all, I am facing a problem when I want to connect Input Module 1766-IQ32T With Micrologix 1100 series B or with 1400 series A, The expansion module doesn't read by RSLOGIX 500 while other modules...
View ArticleMICROLOGIX 1200 COMMS PROBLEM
Hello, I have a micrologix 1200 plc which has faulted. The fault LED is On but not blinking. I cannot go into the plc. I've tried DF1 and DH485 using the 1767-UIC but havent succeded. Is there any way...
View ArticleCommunications Issue
Hello, can someone give me any ideas as to why I can not connect to our SLC 5/04 PLC (1747-L541) I do not have any inputs or outputs hooked up as the plc is out in the open for now in our shop. I have...
View ArticleHow To: Panel View Plus
I am new to panel view all together. I have a panel view plus 1000 and I am trying to connect it to my computer. Any tips and advice to help me get started on setting up my panel view would be...
View ArticleRSLogix w/ Windows 7 Program Editing Problem
Thanks in advance for your help. I am trying to get a copy of RS Logix Micro Starter Lite (Rev. 8.3) running on a Windows 7 laptop, connecting to a MicroLogix 1000 (1761-L32AWA). Everything is up and...
View ArticlePowerflex 40P Failures
We've recently had a rash {almost a dozen} Powerflex 40P drives with Etherent Modules fail. The drive still powers up, but no power is supplied to the Etherent Comm Card. Repalcing the ribbon cable and...
View ArticleFT View Studio, HMI server error with 5 or more displays
trying to open up a project in FT view studio that i had opened up just the other day and its now giving me an error that reads.... The HMI server in area 'project name' refused to load its project....
View ArticleMicroLogix 1500 Controller Fault Question
Good evening, Just had a fault that caused the PLC to not run through the program. The fault was 0479H and I can't find anything on it. I cleared it via my computer and it is working fine currently...
View ArticleCopy INT into second half of a DINT
Hi all, I'm trying to copy an INT into bits 16 to 31 of a DINT for a VSD speed control. It sounds easy in theory, but I'm struggling to find a practical solution. Is there a straight forward way of...
View Articleerror 189h in MicroLogix 1400
i have been trying to download the program attached here but getting a major error ,"Expansion I/O module 1 generated an error." other pre-installed program is running correctly but if i am making...
View ArticleSLC 5/03 AND EZ3 TOUCHSCREEN
A couple of mounths back a posted about the need to replace a no longer available panelview550. I got allot of good feedback and decided to go with a panel from EZ automation and the DH485 network...
View ArticleSLC 5/03 AND EZ3 TOUCHSCREEN
A couple of mounths back a posted about the need to replace a no longer available panelview550. I got allot of good feedback and decided to go with a panel from EZ automation and the DH485 network...
View Article