PowerFlex 700 EDS File Revision 10.002
Hi All. Does anyone has a copy of this EDS file?. Ive been into AB's EDS Database but it doesn't exist (latest revision is 10.001). Unfortunately when I roll back the EDS in my configuration to...
View ArticleML1400 PLC send data directly to FTPC
Hi Everyone , I am trying to Send A JSON data format on a ML1400 plc directly to FTPC.Is this possible? I have notice also on the RSlogix500 software that there is a Tool menu for the Visual Basic ,...
View ArticleStratix Switch Data Type
I currently have a stratix 5700 and when adding the device its data type has an associated DINT called fault. I can't seem to find any information on what this corresponds to and I'm not sure what...
View ArticleMNET to OMNI
Good morning all, does anyone have any experience communicating to an OMNI Flow Computer through a MNET card, Im getting data back but it is not what i expected. Should I be using Enron/Daniels? Byte...
View ArticleFinding a Panelview Tag in the PLC
I have the .mer file for a PanelView program, but not the associated files / folders to actually look under the hood and edit it The PanelView program is live right now and is getting data from one of...
View ArticleWhy is 1492-ACABLE*YD Needed
We are trying to use 1492-AIFM8S-3 module with 1756-IF8I module. RA has a technical post "728767 - Wiring system solutions for 1756-IF8I, 1756-IF8IH, 1756-OF8I and 1756-OF8IH IO modules" showing you...
View ArticleJoin new module for existing Contronet network
Hi guys! Can anybody help me? I have an existing controlnet network. How can I connected a new module? Like an 1794 IB16. What should I need to do after I connected the new module? One more question:...
View ArticleFault 16# 0002 on 1756-DHRIO
I have a 1756-DHRIO on a 1756 controllogix chassis, that is currently showing a minor fault of 16# 0002 No resources. I currently have Channel A on DH+ (flashing green light) and Channel B on RIO...
View ArticleRslinx cannot set port type to 288
Hi guys, I am trying to connect AB compactlogix 1769-L30ER through Ethernet cable to my laptop. I use Rslinx version 3.9 When I enter IP address it can find the CPU without any problem but it does not...
View Article1771-IAD A, B, C, D Terminals
What are the A, B, C, and D terminals used for on a 1771-IAD Input module? All the literature I could find just says that they "are not used" but we have a system in our plant that has 120VAC wired to...
View ArticleUnsupported processor
Hello all, I am trying to open an .rss file with RSLogix 500 and I am getting the following error: Unsupported processor! Please open this project with higher version of this product. OK whatever, so I...
View ArticleFactorytalk View SE Datalogging
Hey Guys, I'm somewhat new to Data logging so try to bare with me. I'm trying to setup Data logging in Factorytalk View SE to log to my SQL database. I have created the 32-bit ODBC system DSN. Created...
View ArticleFixed Cyclic Execution of Motion Tasks
Hi All. Im currently developing a machine program from 2 previous machines- this means im integrating routines from both projects including standard and motion logic. My question however is- 1 program...
View ArticleCLX to Fanuc Remote Start
This might be the wrong forum, so be patient. I've done interfaces, via multiple protocols, to multiple Robot controllers over the years, Kuka, ABB, Espon, Mic, Motoman... Seems like it should, would...
View ArticleRetrofitting old PLC5
I have a customer that is wanting to upgrade his old PLC5 to something newer. I am still pretty new to the PLC world and was hoping to get some insight on possibly what might be the best fit. I still...
View ArticlePV900 Firmware
Dear all Can any one provide me firmware for PV900 2711-K9A8 series D version 3.03. Latest version panelbuilder does not have it. I need file from older version. I think old hardware does not...
View ArticlePLC micro850 connect with HMI Proface GP4000 series
Hi everyone! Is it possible to connect between PLC micro850 with HMI Proface GP4000 series ? If it can do, can you show me how to do it? Thank you in advance!
View ArticleRequest for Android HMI testers
Hello :I'm the creator of an Android HMI app, I recently added Ethernet/IP connectivity with MicroLogix and SLC AB PLCs, but I have only been able to test it with a MicroLogix 1100.I'm really not...
View Article1738-IT2IM12 thermocouple wiring - compensating cable
I'm testing installation of a custom-built machine. The equipment is at room temperature of about 19°C for a couple of weeks but the PLC is reading 25 to 29°C from the J-type thermocouple inputs. I...
View ArticleControlLogix DLL File
Hello, I've been wracking my brain, but I thought I remembered there was a way to store and execute a DLL file inside of a ControlLogix (not softlogix) controller? You could use exposed functions...
View Article