Import/Export on 1756-L55M12 CPU Rev 16
Hi All. For some reason when I create a project for the above CPU in either RSLogix 5000 or Studio 5000 I cannot import or export routines or UDT's. If I choose another CPU (with the same revision)...
View ArticlePanelView Plus 6 1000 weird behavior
Hi all, Recently I upgraded a PVP6 from version 7.0 to version 9.0 since I needed it to communicate with a 5069 CompactLogix Controller (L320ERM V30). I am still developing my app with FTView 7.0...
View Articleconnected users
How can I tell who is connected to the same plc controller using RS Logix 5000? I see the symbol of a pencil come up that another user has changed the program.
View Articlecompactlogix conversion
So i posted here a couple times about converting an existing 5/03 system a 5069 compactlogix processor, lots of good advice so we dove in and bought the stuff ( A 5069-L310ER processor and a 1747...
View ArticleAllen Bradley Panelview .PVA
Is there anyone that is able to open an old panelview file and PDF me the details (screens, tags etc)? I have a project I am unable to open with Panelbuilder 32. It is too old (the file, not...
View ArticleImport data to Micrologix 1100 via Excel?
I have written a fairly complicated (at least for me) program for a Micrologix 1100. I am controlling several Kinetix and Powerflex drives over Ethernet. There is also a Panelview 800 in the system...
View ArticleDeviceNet
I have enjoyed reading the posts on this site for some time now, and I am hoping that someone on here would be able to help me out with a problem. We have a small DeviceNet network consisting of a...
View ArticleCan I wire up Isolated Analog Output card 0-10V to Omron VFD?
Hello Guys, I have an Allen Bradley 1769-OF4VI Isolated Analog Output card 0-10V and I'd like to use it to control speed of an Omron VFD. The VFD has the ordinary frequency analog input where you...
View ArticleMasking array in ladder logic
Hi Guys, I have an Array of BOOL [52].I want to mask this array based on size (SINT) . like if my array size is 12, I want to pass the first 12 elements of Array of Bool and block the rest. I am not...
View Articlehow to logic AND array of bool in studio5000
Hi Guys, Is there a way to logic AND array element in ladder logic studio5000 ? I have Array[BOOL 64], and I want to make sure all the elements are 1 to activate an LED. I was thinking to use FAL...
View ArticlePanel Builder Version Problem
Dear All, I have panel builder 32 3.70v but when i am try to open backup .PVA and .PBA file there is error show file not supported or fil corrupted. I think backup file is making on higher version...
View ArticleFactoryTalk Transaction Manager
I have a configured and working FT Transaction Manager, but the computer it’s installed on needs to be replaced and now I'm trying to install FTTM on different computer. I’m trying to complete the...
View ArticleFacrory Talk Transaction Manager
Hello people. I do not have much experience in this product. My question is: can you have 2 configurations running on the same server? I hope you can help me. Thanks in advance. Mario
View Articlesetting BOOL [64] in Studio 5000
Hi, I need to set an output of bool[64] array when condition triggered but when I download the code to the controller it cause major fault see attached. Can someone help me with that? Thanks
View ArticleFactoryTalk SE Visibility Question
Greetings all, I am attempting to animate a polygon to be visible when the value of a DINT becomes 3 or less. Currently, my script is the simple {[PLC]Test_Dint <= 3}, with the true state radio...
View ArticlePanelView Plus 6 Log Off
We have a panelview plus 6 to a micrologix 1400. Looking to log off the user after 15 minutes if there is no screen activity but only if the machine is in manual mode. We have used the auto log out...
View ArticleMicrologix 1200 major error code 21h
I have a controller micrologix 1200 and it is faulty, major error code 21h "this is a user defined fault code" I need if somebody has experience with this fault (confirm if it is a hardware failure)
View ArticleEthernet/IP to Profinet IO with CompactLogix 1769-L18ER-BB1B
I have an upcoming project that consists of a CompactLogicx PLC with onboard I/O AND ProfiNet I/O Devices on a separate network. This is my first time attempting to connect and control via different...
View ArticleHigh speed counters ML1100
Hi Gurus i understand the ML 1100 has 1 20Khz high-speed counter. The counter has four dedicated inputs ive got inputs I:0/0 and I:0/1 connected to an encoder and it counts away dream and i can see...
View ArticleDownload program to Micrologix 1400
Hello, I'm new to PLC Programming, with just a simple course about the basics. I've got a micrologix 1400 PLC which seems to have had its program wiped when the battery was replaced. I've had the...
View Article