Quantcast
Channel: Allen Bradley / Rockwell Automation Latest Topics
Viewing all 3748 articles
Browse latest View live

VStudio.exe

$
0
0

I have an error when opening my RSView studio.

Login failure for application vstudio.exe

I have heard that there are some files to delete and reinstall or something along those lines.

 

Any  Ideas?????


Studio 5000 Auto Hides Routines

$
0
0

Has anyone seen this before? Where studio 5000 will auto hide your open routines? Then you have to click on the arrows left to activate the routine? 

 

I have a video video but it's too long to post on here. 

Tag passing in FTView ME 5.1 with global objects

$
0
0
I have a global object that I need to use multiple times. The object has three global object parameter definitions (#1-3) and a GoTo Display button that should pass the first tag (#1) to the new display. The GoTo Display button has in the parameterlist written "{#1}" as the manual describes for parameter passing. I have defined the global object parameter definitions in the display section for each reference object, but when testing the application it cannot find a value for the {#1} to pass. It does find the name for the object, that it searches from the PLC tags with the #1 though. The FTView says it cannot find a parameter file for the #1, but currently I'm not using any parameter files. Can't I use the parameter passing for global object parameters? I have tried to insert a direct tag to the {#1} and it works, but I'd rather use the passing since this way I won't need to duplicate the base object for each reference object.

Connecting two faceplates with one global object

$
0
0

Can we connect two faceplates with one global object.i have analog cal. Block and aical alarm block which gives alarm  now i have one global object which connects to aical block.and opens a faceplate.i want to have button on this faceplate which should take me to alarm faceplate. In global object paramter defination i have used #1 for aical block.

And #2 for alarm block .in run time when i click on refernce object it opens the faceplate and shows data from aical block. When i click on alarm button .it takes me to alarm faceplate but doesnt show tag value from alarm block.can anybody help?

# and [ ] with COPY commands?

$
0
0

trying to understand, so that i may modify, a section of logic here and ive come across something i have yet to see in my limited time programming.  the COPY commands here with a # and also a [ ] around the integers is what is confusing me.  from what ive read you need to use the # sign in front of a string integer in order to use the COPY command?  any sort of light shed on ths subject would be greatly appreciated. 

Syntax_Questions.jpg

Syntax_Questions_2.jpg

Gradient Fill on PV7

$
0
0

Hallo Community,

i have the Problem that my complete project is made with grandient objects and my PV cant display that.

When i was making a runtime application i got some warnings.

"<MomentaryPushButton2> on display <Allgemein - PackML_State_Time> is using a Gradient Fill. When running the MER on a PanelView Plus 6 terminal, the system cannot process certain gradient fills. When running the MER on a computer, the system can process all gradient fills, this warning does not apply. Please refer to the online help for more detail on this warning."

I got this message for every button on every side.

The problem is that i dont use PV6 and because of that i thought its ok to ignore the warnings but on PV7 i have also no grandient and my objects are all blank now.

Did i make something wrong?

Thanks in advance!

 

Mit freundlichen Grüßen,

Best regards

Adrian Düringer

Testing a 1762 card of allen bradlley without the plc

$
0
0

i  discover after a default that the led run and the led default of a plc allen bradlley 1200 were alight and it was not possible for me to access to it. i think that it is damaged but the matter is that i don't know how to test  the i/o cards without the plc. i also wanted to know if all i/o diagnostics leds  of the card begin to shine directly when power is on then the one selected by the process remain alight. excuse my English language please i am trying to do my best.

the references of the card are 1762 iq16, 1762iq8, 1762ob16

 

thanks u so much .

MicroLogix 1000 Communication Problems

$
0
0

Trying to Communicate with MicroLogix 1000

I’m very new to PLCs and am having problems with a Micro Logix 1000.

I am currently trying to connect to an Allen Bradley Micro Logix 1000 In order to download the program that is currently on it. This Micro Logix has been in use since the late 90’s and as of recently has started to no longer work properly with a flashing fault LED. Also, the Output LEDs are not on at all. I’m using a windows xp operating system with RSLinx Classic Lite and a USB “programming cable” I got off of Amazon (https://www.amazon.com/dp/B015YSB42K/ref=pe_385040_215884940_TE_3p_dp_i1)

I Installed the driver for this cable from this site (http://www.usb-drivers.org/ft232r-usb-uart-driver.html)

Once I have the PC connected to the Micro Logix 1000 I check the COM port through windows device manager. From this point I go to “Configure Drivers” and select RS-232 DF1. Afterwards I select Auto-Configure, which has always failed for me. Comm port is set correctly with respect to the setting in windows device manager. After Auto Configure failed I started to manually configure the driver with every possible combination of Baud Rate, Parity, and Stop Bits. I left Station Number at 0, Error Checking at CRC and Protocol at Full Duplex throughout manual and auto configuration attempts. I also tried deleting a Harmony.hrc file within the program files of the software and still no luck. Any input on how to solve my problem is greatly appreciated.  


Any experts on DNP 3.0 protocol

$
0
0

Hi everyone. I'm new to this community but finding a lot of useful information and active discussions going on in these forums.  

To those who are familiar with DNP3 protocol and AB products, I was wondering if anyone know whether there is an alternative to Prosoft's current MV169-DNP used on Compactlogix RTU applications.  I've been searching everywhere and can't seem to find a substitute product.  Reason I'm asking is because prices are going up every year for their products (which are already quite costly) and having an alternative means we can be more prepared in case there is any change in the future.

Thanks in advance!

1769-ASCII

$
0
0

I'm using a 1769-ASCII and need help with one part of it.  I have no issues with sending data.  The manufacturer shows the following as the process...

 

ascii_process.PNG

My question is: how do I evaluate the XON\XOFF?  The machine states "This communication protocol tells the status if it can receive any data or not to the host by sending "XON" (HEX 11H) or
"XOFF" (HEX 13H) to the signal line."  I never receive any data so I'm not sure what's wrong or if what I'm doing is correct.  The attached file is same code downloaded from AB's website which is what I based my code off of.

 

http://search.rockwellautomation.com/search?client=samplecode&oe=UTF-8&ie=UTF-8&output=xml_no_dtd&proxystylesheet=samplecode&site=sample_code&getfields=*&lang=en&hl=en&sort=date:D:L:d1&wc=200&wc_mc=1&ud=1&filter=0&q=ASCII

 

62119.exe

PowerFlex 525 EENET

$
0
0
Does anyone happen to have an L5K aoi for PowerFlex 525 EENet drives for use as conveyors? I've done some searching and haven't found anything applicable. Thanks! TL7791

Message from 1761 net-eni to 1756 enbt

$
0
0
Help Forum! I am having trouble with a communication path for a message originating in a compactlogix controller to a 1761 net-eni to compactlogix controller with a 1756 enbt built in ethernet port. I can message out of the latter controller to the net-eni controller (I have others with net-eni's) with this path: LocalENBT, 2, IP address, 3,1. My net-eni has the processor with the enbt addressed at node 49 with just the IP address. If I enter the path as 2,49 I get an error "messaging connection lost". What am I missing?

Micro820 MSG to SLC 5/03 via 1761-NET-ENI

$
0
0

I am currently trying to message from  a micro820 to a SLC 5/03 (via 1761-NET-ENI ser. D).  In the 800 messaging manual (

http://literature.rockwellautomation.com/idc/groups/literature/documents/qs/2080-qs002_-en-e.pdf)

, there is a CIP generic message example that gathers the CatalogID of the device at a particular I address.

 

My micro is 192.168.10.23.

My 1761-NET-ENI is 192.168.10.22.

I can get online with both, and I see both processors in Linx.  However, when I execute the example code in the micro, the CatalogID is not the SLC, but the 1761-NET-ENI.

All I need to do is write an ASCII string to the SLC 5/03.

 

NOTE*** Ultimately, I will not need to speak DIRECTLY from the 820 to the SLC--instead the Micro820 will send a CIP message (...a barcode string) to a server that will then send a bunch of data to the SLC 5/03.  So:

 

BARCODEà[ASCII]àMicro820à[Ethernet]àServer(gets a bunch of data)à[Ethernet]à1761-NET-ENIà[DF1]àSLC5/04(oldPLC)

 

PLC5 PID translation / conversion to ControlLogix

$
0
0

Hi folks,

I'm in the midst of doing my first translation from 5 to 5000 that also includes PID instructions.  I've done a couple that have not.  I'm just looking for any helpful tips or tricks you may have that are PID specific.

The L71 logix processor will run the original 1771 IO over RIO via DHRIO modules.  Analog modules are 1771 NIC and NOC.

The original PLC5 program contained a 100 msec STI file in which all the PIDs were run.  All have 100 msec update times.  The translated program has them all in an STI file as well.  100 msec timing confirmed.

I've looked through some docs in the Rockwell tech KB and I see the phrase "many things do not translate" (or something similar).  Looking through and comparing the first one I found, I think I understand most things that do translate and they look ok.

I see, on the scaling page, min/max for cv.  Both are zero.  This is obviously different from low/high cv limits on the config tab.  I assume leaving these zeros is a bad thing and the output would not work if left as is.  Correct?

Any other things I should pay close attention to?  Is there a specific Rockwell doc I should be reading?

As always, your input and feedback is very much appreciated.  Many thanks in advance.

Printer for Panelview 600?

$
0
0
Hello Friends
I have a Panelview 600 with printer port, I need to print the alarm log a time for week.

I have used in other projects Epson LX-300, but now it is discontinued.
I have seen the Epson LX-350 but I am not sure if it would function.

Has somebody used this printer?
What other printer do you recommend?

Thanks in advance.

Micrologix 1100 to Powerflex 525 Ethernet Comm loss

$
0
0

I am setting up a Micrologix 1100 to communicate with a Powerflex 525 over Ethernet via messaging.  Everything works well so far.  I just realized though that if I lose my Ethernet cable for whatever reason I have no way of telling the PLC that there is a com loss.  I can monitor a drive fault as long as the cable is there but if the cable is disconnected or breaks the drive will fault and shut off but the rest of my machine will still keep going which would be bad.

Long story short is there something that changes state when I fail to communicate with the drive (be it reading or writing) that I can use some where else in the program to shut the system down?

RsLogix 1400 to PC

$
0
0

hi folks,

Someone had previously set up Allen Bradley RsLogix 1400 PLC on our mobile conveyor system that is working just fine. i want to view the logic on my laptop pc but could not establish network connection between my pc and the plc.

would some one please help with tips on how i could establish connection.

 

thanks,

FactoryTalk View DINT to ASCII conversion

$
0
0

Would someone please help me how to convert an integer to ascii?   For example if the output tag is an ascii string, of 3 characters and my numeric input is integer.   When user input a value of 5, I would like the input value to be convert and assign to output ascii string tag of "005".  How do I set the conversion format in either tag assignment or tag expression?

Program a plc from an Excel spreadsheet?

$
0
0
I'm a long-time rung monkey, and ladder logic is the only tool I've ever used to program a plc. I've heard on several separate occasions that a plc can be programmed from code developed solely in an Excel spreadsheet. I've only ever heard this from someone who did not do it himself, but knows somebody who did it. My question is, can it be done? And if so, just how does one go about it? And can it been done on AB plc's? LuckyHack

Kinetix 300 not faulting

$
0
0

I am connecting a Kinetix 300 servo drive to a MicroLogix 1100 over Ethernet.  The connection works fine and the drive responds as it should.  When I disconnect the Ethernet cable I should get an E14 fault and the drive should shut down.  I am not getting that fault and the drive continues to turn.  I have a comm loss signal in the PLC because of a msg error but can't stop the drive because I am not connected anymore.  I can disable the drive but as soon as I enable it again the motor starts to turn again because the motion profile is retentive.  I tried the same thing on the Powerflex 525 that is connected the same way and it immediately goes into a fault.

Why am I not getting the fault message on the Kinetix? 

Viewing all 3748 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>